SKU: LPE2-11 Category:
Delivery and return
Delivery and return

Next day delivery in store

Buy before 6pm to receive your order next day.
FREE

Next day delivery

Orders before 6pm from Monday to Saturday (or before 1pm on Sunday) will be delivered Next working day (except Northern Ireland and Highlands). Orders placed after 6pm (after 1pm on Sunday) or for Northern Ireland and Highlands will be delivered in 2 working days.
29 USD

Drop Point

In 2-3 working days. Pick up your parcel in one of the many diferent collection points available and during a wide range of hours.
39 USD

Same day delivery in London:

Place your order before 13:00 to get it today!. If you order later on, you’ll receive it the next day and if you order on Sunday, you’ll receive it the next working day.
59 USD
Shipping Information
Shipping Information

SHIPPING

Complimentary ground shipping within 1 to 7 business days In-store collection available within 1 to 7 business days Next-day and Express delivery options also available Purchases are delivered in an orange box tied with a Bolduc ribbon, with the exception of certain items See the delivery FAQs for details on shipping methods, costs and delivery times
Composition and care
Composition and care

Characteristics of wood :

  • Hard, compact , fiberous and porous
  • Good wood gives a rich, warm and beautiful surface.

Wood is used for the construction of:

  • Floor, Furniture, Walls
  • Incidental furnishing (lampshades, picture frames)
  • Kitchen & restaurant ware

Description

A “vertical multi-stage pump” also known as “vertical centrifugal pump” uses a unique configuration between the shaft and bearing support that allows the volute to hang in the sump while the bearings remain outside the sump. This type of pump doesn’t use a stuffing box (assembly containing a gland seal; prevents leakage between moving parts) but instead a “throttle bushing”.

Application Limits of Vertical Multistage Pump

  • Medium temperature: normal type: 0℃~68℃ hot water type: 0℃~120℃
  • Ambient temperature: +40℃
  • Max ambient pressure: 1.0MPa
  • Advisable to use a motor of a higher power in case that the density or viscosity of the medium is above that of water.
  • pH: 5 to 8

Application Fields of Centrifugal Pump

Water supply BL BL T
Filtration and transfer at waterworks
Distribution from waterworks
Pressure boosting in mains
Pressure boosting in high-rise buildings, hotels, etc.
Pressure boosting for industrial water supply
Industry
Pressure boosting
Process water systems
Washing and cleaning systems
Vehicle washing tunnels
Fire fighting systems
Liquid transfer
Cooling and air-conditioning systems(refrigerants)
Boiler feed and condensate systems
Machine tools(cooling lubricants)
Aquafarming
Transfer
Oil and alcohol
Glycol and coolants
Water treatment
Ultra-filtration systems
Reverse osmosis systems
Softening, ionizing, demineralizing systems
Distillation systems
Separators
Swimming baths
irrigation
Field irrigation(flooding)
Sprinkler irrigation
Drip-feed irrigation

Electric Motor

  • Full-enclosed and ventilating two-pole standard motor
  • Protection class: IP55
  • Insulation class: F
  • Standard voltage Single phase 220V-50Hz Three-phase: 380/400V-50Hz
  • Standard motor efficiency: 11kW to 45kW: IE3, other: IE2, specific efficiency value for below table

Calculation of minimum Inlet Pressure

If the pressure in the pump is lower than the vapor pressure of the medium, cavitation will occur, which will affect the performance of the pump. To avoid the cavitation and ensure the pump inlet has a minimum pressure, the maximum suction head should be calculated as below:

H=Pbx10.2-NPSH-Hf-HV-Hs

Pb: Atmospheric pressure, bar (In close pipeline system, it can be considered as the system pressure);
NPSH: Net positive suction head, m (Value at a maximum flow of Q-NPSH curve);
Hf: Suction pipeline loss (Value at a maximum flow of the corresponding pipeline);
Hv: Medium vapor pressure, m (Medium vapor pressure at corresponding temperature, the default medium is water, as shown in figure4 on the right);
Hs: Safety margin, m, general value is 0.5.
Calculation result: if H is positive, the pump is installed in a suction way, otherwise, it is installed in the downdraft way.

Note: It is not necessary to do the above calculation under general conditions. Only when we use the pump in the following situations do we need to calculate the H:
1. Medium temperature is high;
2. The velocity of flow is larger than the rated value;
3. Suction head is big or the inlet pipeline is long;
4. System pressure is small;
5. Inlet condition is bad.

 

Calculation of minimum Inlet Pressure

Selection of Pumps

Selection of pumps should be based on:

  1. Duty point of the pump
  2. Dimensional data such as pressure loss as a result of height differences, friction loss in the pipework
  3. Pump efficiency
  4. Pump materials
  5. Pump connections
  6. Commonly used mechanical seal configuration tables

1. Duty point of the Pump
From a duty point, it is possible to select a pump on the basis of the curve charts shown in “performance curves/technical” data.

2. Dimensional Data
When sizing a pump the following must be taken into account:

  • Required flow and pressure at the draw-off point.
  • Pressure loss as a result of height differences.
  • Friction loss in the pipework (Hf) (Refer to Fig.1) it may.
  • Highest efficiency at the estimated duty point.
  • NPSH value.
  • For calculation of the NPSH value, see the corresponding curves chart.

3. Pump Efficiency
Before determining the best efficiency point, the operation pattern of the pump needs to be identified. If the pump expected to operate as the same duty point, then select a BL pump which is operating at a duty point corresponding with the best efficiency of the pump.
As the pump is sized on the basis of the highest possible flow, it is important always to have the duty point to the right on the efficiency curve (eta) in order to keep efficiency high when the flow drops.

4. Pump Material
The material variant should be selected based on the liquid to be pumped. BL wetted parts are made of AISI304. BLT pump body is made of cast-iron.

5. Pump Connections

The selection of pump connection depends on the rated pressure and pipework. The vertical centrifugal pump offers a wide range of flexible connections such as:

  • Pipe thread
  • Oval flange
  • DIN flange
  • Other connections on request
  • Commonly used mechanical seal configuration tables

6. Commonly used mechanical seal configuration tables

Configuration Configuration illustrate Application Field Configuration case
EUBV Container-type E, hard alloy moving ring U, static ring leaching resin graphite B, fluorine rubber V 1. Working condition regular under cold water 0 ℃ to 68 ℃, no particles, oil.
2. Working condition regular under hot water 68 ℃ to 90 ℃, no particles, with oil.
Normal
EQQE Container type E, moving ring and static ring silicon carbide Q, EPDM E Working condition: hot water 90 ℃ to 120 ℃, containing a small number of particles, no oil. Normal
EQQV Container type E, moving ring and static ring silicon carbide Q, fluorine rubber V 1. PH = 5-7 acidic medium.
2. PH = 7-9, alkaline medium.
3. Working conditions: hot water 68 ℃ to 90 ℃, containing a small number of particles, oil.
4. With oil.
Customer-made
EUUE Container type E, moving ring and static ring U, hard alloy U, EPDM E 1. Under ice water 0 ℃.
2. A crystallization of alkaline medium.
3. Containing a large number of granular media.
4. More than 2 MPa pressure conditions.
5. No oil.
Customer-made

Maximum Work Pressure

Model Curve No.
BL(T)2,4 2
BL(T)8,12,16,20 3
BL(T)32-2-2~BL(T)32-7 1
BL(T)32-8-2~BL(T)32-12 4
BL(T)32-13~BL(T)32-15-2 5
BL(T)45-2-2~BL(T)45-6 1
BL(T)45-7-2~BL(T)45-9 4
BL(T)45-10-2~BL(T)45-13-2 5
BL(T)64-2-2~BL(T)64-5-2 1
BL(T)64-5-1~BL(T)64-8 4
BL(T)90-2-2~BL(T)90-4-2 1
BL(T)90-4~BL(T)90-6 4

Maximum Ambient Temperature

When the pump is operating in a place where the ambient temperature is higher than 40℃ or altitude is higher than 1000m, the output power of motor P2 will decrease because of poor cooling caused by low air density. Therefore, in that case, the vertical pump should be equipped with a high-power motor.

 

×